UFC APEX FIRES
1,289Governing occupant load
3Approved bleacher configurations
2,563Exit capacity provided
1Permit covering the full calendar
Special Events · Permit

Approved Envelope

The outer boundary of what the facility may operate under this permit. A layout inside the criteria operates within the approved analysis; a layout outside it is a separate submittal.

ParameterBasisLimit
Occupant load, event spaceConfiguration 1, Hussey Seating manifest MP-011,289
Bleacher seatingManifests MP-01, MP-02, MP-03, order O-108580829 max
Event floor seatingPermit condition, below calculated floor capacity of 646400 max
Mezzanine level889 sq ft at 15 net sq ft per occupant60
Permitted configurationsThree deployed bleacher arrangements1, 2, 3
Required egress width1,289 occupants at 0.15 in. per occupant194 in.
Exit capacity serving the event spacePhase 1 and Phase 2 Master Egress Plans2,563

2,563 persons of exit capacity against 1,289 required — the exit system carries nearly double the governing load.

Configuration 1Governs
1,289
Total occupant load
Bleacher829
Floor400
Mezzanine60

Full deployment. All twelve sections deployed, Bank B full open at ten rows. Manifest MP-01.

Configuration 2Reduced
1,189
Total occupant load
Bleacher729
Floor400
Mezzanine60

Bank B1 removed from service, west banks retracted. Manifest MP-02.

Configuration 3Alternate
1,194
Total occupant load
Bleacher734
Floor400
Mezzanine60

West banks partial, suite area adjacent to north sections. Manifest MP-03.

Margin
2,563 persons of exit capacity against 1,289 required — the exit system carries nearly double the governing load.
Floor seating
Floor seating is a permitted maximum, not a fixed layout, because it changes with every production. Any layout meeting the aisle, cross aisle, and row criteria and the permitted seat maximum operates within the approved analysis without a separate submittal.